<rss version="2.0" xmlns:atom="https://www.w3.org/2005/Atom">
  <channel>
    <title>Research in Progress (RIP)</title>
    <link>https://rip.trb.org/</link>
    <atom:link href="https://rip.trb.org/common/TRIS Suite/feeds/RSS.aspx?s=PHNlYXJjaD48cGFyYW1zPjxwYXJhbSBuYW1lPSJkYXRlaW4iIHZhbHVlPSJhbGwiIC8%2BPHBhcmFtIG5hbWU9InN1YmplY3Rsb2dpYyIgdmFsdWU9Im9yIiAvPjxwYXJhbSBuYW1lPSJ0ZXJtc2xvZ2ljIiB2YWx1ZT0ib3IiIC8%2BPHBhcmFtIG5hbWU9ImxvY2F0aW9uIiB2YWx1ZT0iMTYiIC8%2BPC9wYXJhbXM%2BPGZpbHRlcnM%2BPGZpbHRlciBmaWVsZD0iaW5kZXh0ZXJtcyIgdmFsdWU9IiZxdW90O1JlaW5mb3JjaW5nIHN0ZWVsJnF1b3Q7IiBvcmlnaW5hbF92YWx1ZT0iJnF1b3Q7UmVpbmZvcmNpbmcgc3RlZWwmcXVvdDsiIC8%2BPC9maWx0ZXJzPjxyYW5nZXMgLz48c29ydHM%2BPHNvcnQgZmllbGQ9InB1Ymxpc2hlZCIgb3JkZXI9ImRlc2MiIC8%2BPC9zb3J0cz48cGVyc2lzdHM%2BPHBlcnNpc3QgbmFtZT0icmFuZ2V0eXBlIiB2YWx1ZT0icHVibGlzaGVkZGF0ZSIgLz48L3BlcnNpc3RzPjwvc2VhcmNoPg%3D%3D" rel="self" type="application/rss+xml" />
    <description></description>
    <language>en-us</language>
    <copyright>Copyright © 2026. National Academy of Sciences. All rights reserved.</copyright>
    <docs>http://blogs.law.harvard.edu/tech/rss</docs>
    <managingEditor>tris-trb@nas.edu (Bill McLeod)</managingEditor>
    <webMaster>tris-trb@nas.edu (Bill McLeod)</webMaster>
    <image>
      <title>Research in Progress (RIP)</title>
      <url>https://rip.trb.org/Images/PageHeader-wTitle-RIP.jpg</url>
      <link>https://rip.trb.org/</link>
    </image>
    <item>
      <title>Feasibility of Engineered Cementitious Composites (ECC) as Joint Material for Accelerated Bridge Construction (ABC)</title>
      <link>https://rip.trb.org/View/2694442</link>
      <description><![CDATA[Advancements in manufacturing methods and the growing demand for high-strength materials in reinforced concrete have led to the development of steel reinforcing bars with strengths exceeding 100 ksi. These ultra-high-strength bars hold significant promise for bridge construction, as they could extend feasible span lengths beyond those achievable with conventional reinforcement while still meeting strength and serviceability requirements. Their use can also reduce girder depth, leading to material savings and lower overall construction costs. However, successful implementation requires addressing key concerns regarding serviceability and durability. Critical factors include corrosion resistance, structural behavior, and ductility of beams reinforced with these high-strength bars. 
The primary objective of the proposed work is to investigate the durability (corrosion resistance) and serviceability of concrete girders reinforced with very high-strength reinforcement, by testing bond-slip relationship between corroded and non-corroded steel rebars and concrete. 12 medium-span (8 in x 12 in x 10 ft) concrete beams will be cast and tested for strength and ductility. Six of the 12 beams will be subjected to accelerated corrosion. Under controlled conditions, the research team will test the strength and ductility characteristics of the beams reinforced with these bars. 
This study directly supports the mission of the Center for Healthy and Durable Transportation (CHDT), a University Transportation Center (UTC), whose primary research focus is enhancing the durability and service life of transportation infrastructure through innovative construction materials and techniques. By addressing the performance of very high-strength reinforcing bars in reinforced concrete girders and their behavior under corrosive conditions, this project advances the application of durable, next-generation materials for transportation infrastructure.

]]></description>
      <pubDate>Tue, 21 Apr 2026 13:16:30 GMT</pubDate>
      <guid>https://rip.trb.org/View/2694442</guid>
    </item>
    <item>
      <title>2503 Enhancing MALP and MKP as Repair Materials Through Joint Usage and in combination with Ceramic Paint</title>
      <link>https://rip.trb.org/View/2606541</link>
      <description><![CDATA[The purpose of this research is to address the corrosion performance of conventional reinforcing steel in uncracked and cracked magnesium-aluminum-liquid-phosphate (MALP) concrete and magnesium-potassium-phosphate (MKP) concrete in simulated repairs of Portland cement of both high and low quality. Reinforcing bars will be evaluated in both a clean and passive state and in an actively corroding state. The project will evaluate the ability of MALP concrete to withstand freeze-thaw cycles both as an individual material and in conjunction with Portland cement concrete. CeramycGuard will be investigated as a possible method to limit the penetration of salt solution into MKP to improve the corrosion resistance provided to reinforcing steels.]]></description>
      <pubDate>Fri, 03 Oct 2025 12:05:58 GMT</pubDate>
      <guid>https://rip.trb.org/View/2606541</guid>
    </item>
    <item>
      <title>Capacity and Acceptance Criteria of Welded Splices on Cold-Bent Reinforcing Steel</title>
      <link>https://rip.trb.org/View/2323252</link>
      <description><![CDATA[The American Association of State Highway and Transportation Officials (AASHTO) Load and Resistance Factor Design (LRFD) Bridge Design Specifications require welding of bridge reinforcing steel (rebar) splices to conform to the American Welding Society (AWS) D1.4 Structural Welding Code – Steel Reinforcing Bars. Alaska Department of Transportation and Public Facilities (DOT&PF) uses cold-bent reinforcing steel hoops and spiral bars as confinement in its concrete-filled steel pipe pile bent system. Structural adequacy of this system is essential for seismic performance. In Alaska, and other seismic states, ASTM A706 Grade 60 reinforcing steel (rebar) is 
routinely specified for members expected to form plastic hinges. A706 rebar has a 
restricted chemical composition and carbon equivalent to enhance its weldability.
AWS D1.4 describes filler metal selection, preheat/interpass temperatures and 
performance and procedure qualification requirements for welding of steel reinforcing 
bars. However, welded splices on hoops and spiral bars are technically not in 
compliance with AWS D1.4, which does not allow welding within two bar diameters of 
the bent portion of the steel. Despite this AWS D1.4 code provision and decades of 
research on the pipe pile system, no known defects have arisen from these welded 
splices. However, the reliability of the splices to behave as anticipated is extremely 
important in plastic hinge regions. Specific testing of cold-bent reinforcing steel welds
has not been completed to ensure that current materials and methods would not 
adversely affect the strength and ductility of the reinforcing bars. 
The goal of this research program is to investigate the effect of welding on cold-bent 
ASTM A706 Grade 60 reinforcing steel. Specific objectives are (1) to determine 
changes in microstructure and microhardness in the heat-affected zone (HAZ) of 
welded cold-bent reinforcing steel, (2) to compare the tensile strength and ductility for
welds made on cold-bent versus unbent reinforcing steel, (3) to determine the 
monotonic stress-strain behavior locally in the HAZ of welded cold-bent reinforcing 
steel, and (4) to identify specific requirements and/or acceptance criteria for welding on 
cold-bend reinforcing steel beyond those in AWS D1.4.]]></description>
      <pubDate>Wed, 17 Jan 2024 16:12:52 GMT</pubDate>
      <guid>https://rip.trb.org/View/2323252</guid>
    </item>
    <item>
      <title>Corrosion Performance Overview of Existing Concrete Reinforcement Options</title>
      <link>https://rip.trb.org/View/2244516</link>
      <description><![CDATA[Previous research has examined the corrosion resistance properties of different concrete reinforcement options (e.g., ChromX, hot dip galvanized, continuous hot dip galvanized, epoxy coated, black steel). But further work is needed to understand the behavior of rebar when exposed to chlorides. With better data on reinforcing steel performance, Kentucky Transportation Cabinet's (KYTC's) Division of Structures can incorporate more effective rebar into the design of structures with an eye toward reducing future maintenance costs. Exposing rebar samples to chlorides and accelerated weathering in a salt-fog chamber is a useful testing strategy for determining to what extent reinforcing steel resists corrosion. The project will identify concrete reinforcement options (i.e., type and size) to analyze, perform accelerated weathering testing and evaluate rebars for loss of material, and test pre- and post-accelerated weathering samples to assess variations in mass and tensile properties (i.e., tensile strength, yield strength, percent elongation).]]></description>
      <pubDate>Thu, 14 Sep 2023 08:49:32 GMT</pubDate>
      <guid>https://rip.trb.org/View/2244516</guid>
    </item>
    <item>
      <title>Develop/Refine Design Provisions for Headed and Hooked Reinforcement</title>
      <link>https://rip.trb.org/View/2056301</link>
      <description><![CDATA[The usefulness of reinforced concrete is dependent on sufficient anchorage between concrete and reinforcing steel. Sufficient anchorage occurs when reinforcing steel is embedded into the concrete a distance referred to as the development length. When this length of embedment is achieved the reinforcing steel is expected to reach or exceed stresses beyond yield. Geometric constraints within structural members may prevent straight lengths of reinforcement from developing their yield strength, such as straight bars being terminated within a beam-column joint. In these cases, the addition of a hook or headed bar attachment provides a more efficient anchorage mechanism compared to straight bars. Both hooked and headed bars have shorter development lengths than straight bars. However, the current American Association of State Highway and Transportation Officials (AASHTO) Load and Resistance Factor Design (LRFD) Bridge Design Specifications (9th edition) has not developed standard details for headed reinforcement in bridge structures. In addition, current AASHTO LRFD design provisions for hooked bars are adapted from the American Concrete Institute (ACI) 318-14 Building Code Requirements for Structural Concrete. Considerable revisions to the current ACI 318-19 specification for the design of hooked reinforcement, which require increased lengths (50 to 70 percent longer) relative to previous code cycles, necessitates Texas Department of Transportation (TxDOT) to revisit its current design practice for hooked reinforcement. This research seeks to provide TxDOT with clear and concise design guidance for engineers to use both hooked and headed bar attachments in TxDOT bridge structures. The research teams will accomplish this through large-scale experimental testing of specimens with hooked and headed bars representative of TxDOT bridge structures and current design practice.]]></description>
      <pubDate>Thu, 03 Nov 2022 16:48:28 GMT</pubDate>
      <guid>https://rip.trb.org/View/2056301</guid>
    </item>
    <item>
      <title>Monotonic and cyclic behavior of high strength reinforcing steel (HSRS) after high temperature exposure</title>
      <link>https://rip.trb.org/View/1948951</link>
      <description><![CDATA[Conventional reinforced concrete transportation structures in North America often use Grade 60
reinforcing steel with a yield stress of 60 ksi. The introduction of high strength reinforcing steel
(HSRS) with higher yield strength in the reinforced concrete industry has led to many economic
and workability advantages such as construction time saving, reduced labor cost and steel
consumption which in turn alleviates congestion of reinforcement, savings in transportation and
deliveries that finally results in lower carbon emission. Despite these benefits, many states,
including those in Region 6, have not widely adopted the use of higher strength reinforcing
steels in practice due to lack of knowledge and comfort level with implementing new
technologies and techniques, and the serviceability and durability concerns. In addition, bridge
surveys among 18 states have shown that fire has caused more bridge collapses than
earthquakes. In general, there are three common types of ASTM steel bars that are produced
with yield stresses above 60 ksi: ASTM A615, ASTM A706 and ASTM A1035 (CL, CM and CS
based on carbon and chromium content). Given the lower ductility of HSRS rebars compared to
conventional reinforcement along with the lack of knowledge on different types of HSRS and
their behavior when exposed to elevated temperatures, studying the behavior of HSRS after
high temperature exposure is deemed to be necessary.
In this study, four different tests will be conducted on three different ASTM reinforcement (A615,
A706, and A1035): monotonic and cyclic tensile tests (high strain low cycle), pullout and endbeam
bond tests. Each test shall be performed at both ambient and elevated temperatures.
After the test, each specimen will be analyzed using Energy dispersive X-Ray (EDX) and
scanning electron microscopy (SEM) to investigate the possible change in material composition
and failure analysis of fracture surfaces, respectively. The results will be reported and compared
with the previous studies on conventional and HSRS reinforcements.
The results of this study will allow states and authorities to make more informed decisions
based on the enhanced knowledge on the behavior of HSRS in reinforced concrete
transportation structures such as bridges.]]></description>
      <pubDate>Mon, 09 May 2022 06:15:40 GMT</pubDate>
      <guid>https://rip.trb.org/View/1948951</guid>
    </item>
    <item>
      <title>Condition Dependent Performance Based Seismic Design Phase I</title>
      <link>https://rip.trb.org/View/1890619</link>
      <description><![CDATA[This project defines the framework for Condition Dependent Performance Based Seismic Design (CD-PBSD), which is based on recent research at NC State, and will conduct large scale tests on bridge columns with corroded reinforcing steel. The resulting tests will provide data for model calibration that can then be used in a future phase to conduct large scale analysis to assess the impact of structural condition on response. Tasks will include a literature review, large scale tests on columns with corroded steel, verification of computational model and Buckled Bar Tension (BBT) test results, the development of Phase 2 plan, and a final report with preliminary recommendations.]]></description>
      <pubDate>Mon, 08 Nov 2021 14:13:31 GMT</pubDate>
      <guid>https://rip.trb.org/View/1890619</guid>
    </item>
    <item>
      <title>Corrosion propagation monitoring legacy samples and forensic analysis on selected samples.</title>
      <link>https://rip.trb.org/View/1872934</link>
      <description><![CDATA[In the past, most studies trying to understand corrosion of reinforcing steel, due to project duration limitations: usually terminate the tests shortly after corrosion initiates.  In opposition thereto, some studies have been carried out to better understand the amount of corrosion products that cause cracks (typically in concrete with no supplementary cementitious materials), used methodologies to accelerate corrosion of the reinforcing steel. But, corrosion products built up from accelerated approaches might deviate significantly from the built up that take place under natural corroding (or moderately accelerated) cases.
Legacy samples exposed outdoors for 27 years and indoor samples prepared in 2016 (binary and ternary concrete mixes) will be used to investigate corrosion propagation. For outdoor samples, it is known that a number of rebars are corroding and several samples now display cracks. Similarly, the rebar of several indoor samples are corroding. Monitoring the propagation stage for a long period of time is relevant. TriDurLE Year 1 funded the monitoring of legacy samples. Year 2 will allow to continue monitoring and to assess corrosion extent on selected samples that will be terminated (forensic analysis). If possible, the chloride concentration at the rebar depth will be determined on terminated samples. In addition, the steel bars will be cleaned and the corrosion morphology examined. The maximum corrosion pit depth will be measured and the cross sectional loss of steel bars will also be estimated.
]]></description>
      <pubDate>Tue, 17 Aug 2021 17:16:13 GMT</pubDate>
      <guid>https://rip.trb.org/View/1872934</guid>
    </item>
    <item>
      <title>Impact of Construction Eccentricity on Direct Pier-to-Pile Connections for Permanently Cased Shaft (CFST) Piles</title>
      <link>https://rip.trb.org/View/1846298</link>
      <description><![CDATA[For seismic design of transportation structures, there are competing demands including: economy, strength, stiffness, inelastic deformation capacity, and seismic resilience. Prior research at the University of Washington (UW) demonstrates that concrete-filled steel tubes (CFSTs) can meet these competing demands. This proposed research builds on the prior CFST research to develop direct pier-to-pile connections specific for use in wide range of transportation systems including bridges, high speed rail (HSR), and port structures. Initially finite element analyses (FEA) were conducted to develop the connection and experimental test matrix. Specific study parameters include embedment depth and the addition of a ring to enhance mechanical bond. This initial study resulted in an initial test matrix that is currently being conducted, to study these aspects of the connections. However, there is an important, yet unstudied parameter, which is the placement of the reinforcing steel cage. In construction, it is likely that the pier will not be placed at the exact center of the pile, but instead will be placed with some eccentricity relative to the center of the pile. This eccentricity is likely to be very important but is not possible to study analytically. Here, it is proposed to investigate the impact of eccentricity on the transfer mechanism and damage using large-scale experimental specimens. It is expected that two tests will be conducted which will be complementary with and extend current research that is being sponsored by Pacific Earthquake Engineering Research (PEER) center (referred to as PEER herein). The results will be used to determine design methods and nonlinear analytical models for these new connections.]]></description>
      <pubDate>Mon, 12 Apr 2021 15:37:26 GMT</pubDate>
      <guid>https://rip.trb.org/View/1846298</guid>
    </item>
    <item>
      <title>Design of Long-lasting Discrete Sacrificial Anode for Corrosion Mitigation of Reinforcement in Chloride Contaminated Concrete</title>
      <link>https://rip.trb.org/View/1743218</link>
      <description><![CDATA[Reinforcement corrosion induced by chloride contamination is a leading cause of structural damage and premature degradation in reinforced concrete (RC) structures, with significant implications for safety, reliability, economics, and environmental performance. Discrete sacrificial anode (DSA) is one tool used for corrosion mitigation of steel reinforcement in chloride contaminated concrete, particularly through embedment in repair mortar to reduce the detrimental “ring effect”. The research team's recent study revealed that the commercial DSA products actually have much shorter service life than expected, because zinc corrosion products accumulate at the interface between zinc core and the packaged mortar, reduce the current supply to steel reinforcement, crack the encased mortar, and finally lead to the complete failure of the DSA. In this context, the overarching goal of this project is to design long-lasting DSA to prolong its service life and reduce the costs associated with the need for frequent replacements. To achieve the goal, this study aims to: (1) design conductive and porous foamed cement paste as the encasing material for DSA; and (2) characterize the effects of different components of the paste on the life-cycle performance of newly-designed DSA and assess its effectiveness on the rehabilitation of salt-contaminated RC.

Specifically, carbon fibers will be incorporated into the foamed cement paste to increase its electrical conductivity. Light weight aggregates with water or saturated calcium hydroxide (Ca(OH)2) encapsulated inside will be used in the paste to maintain a sufficient level of moisture. Electrochemical tests will be conducted to study the corrosion performance of steel bars and zinc anodes as well as evaluate the effectiveness of DSAs. Scanning electron microscopy (SEM), Energy dispersive X-ray spectroscopy (EDX), and X-ray diffraction analysis (XRD) will be employed to investigate the mechanisms related to how the foamed microstructure and different components of the paste enhance the longevity and performance of DSAs.]]></description>
      <pubDate>Tue, 06 Oct 2020 13:49:35 GMT</pubDate>
      <guid>https://rip.trb.org/View/1743218</guid>
    </item>
    <item>
      <title>Efficacy of the Bacteria Encapsulation Concrete Self-Healing Method in a Harsh Environment</title>
      <link>https://rip.trb.org/View/1313521</link>
      <description><![CDATA[Concrete is the most widely used material in construction, offering advantages in terms of moisture and fire resistance, versatility, cost, energy-efficiency, and environmental impact. Concrete provides a relatively high level of compressive strength; its tensile strength, however, is fairly low, and concrete members crack on the tension side under the application of small loads. Hence, most concrete systems generally incorporate reinforcing steel to resist tensile. While reinforcing steel receives a certain level of protection against corrosion from the surrounding concrete, the corrosion of reinforcing steel is still a predominant factor undermining the longevity of the vast concrete-based infrastructure. The presence of both air and water is required for corrosion activity to start, and, after tensile crack formation, it will accelerate. However, corrosion may be slowed down considerably if the diffusion of oxygen and harmful ions, such as chloride ions, through the concrete could be reduced. The new concept of self-healing concrete was introduced over the past decade, and many researchers are still investigating the feasibility of the process at a laboratory scale. There are two objectives for the self-healing concrete: (1) recovery of strength after the formation of cracks and (2) sealing the cracks to prevent further concrete deterioration, such as that resulting from corrosion. Several approaches for concrete self-healing are proposed in the literature, such as bacteria encapsulation, mineral admixture, chemical in glass tubing, etc. Most of the proposed methods focused on the second objective and showed promising results for eliminating or reducing the cracks that form first, when the concrete is still relatively young, under dry or wet conditions. However, very few studies have been done to show the versatility and repeatability of some the most promising approaches, such as bacterial encapsulation.]]></description>
      <pubDate>Tue, 24 Jun 2014 01:00:37 GMT</pubDate>
      <guid>https://rip.trb.org/View/1313521</guid>
    </item>
    <item>
      <title>Survey, Evaluation, and Long-Term Monitoring of the EDC GRS Abutment Performance for Multiple-Span CDOT Bridges Replacement Project</title>
      <link>https://rip.trb.org/View/1278688</link>
      <description><![CDATA[The Colorado Department of Transportation's (CDOT's) project to replace the twin bridges over the Union Pacific Railroad and Smith Road incorporates innovations that implement the Colorado Department of Transportation/Federal Highway Administration (CDOT/FHWA) mandate - EDC GRS (Geosynthetic Reinforced Soil) abutment technology. These twin bridges carry I-70 eastbound and westbound traffic on three-span horizontally curved steel welded-plate girder structures. The mid-span piers are founded on deep foundation; however, the GRS abutments are supported by spread footings and founded on embankments. This unique feature of a GRS transition zone, to a GRS abutment founded on an embankment (shallow foundation), to pier (deep foundation) is a new design methodology for eliminating bridge bumps. The objective of this study is to validate the performance of GRS abutment for multi-span bridges and the use of geofabric without positive connections to the fascia blocks for GRS retaining walls.]]></description>
      <pubDate>Sat, 30 Nov 2013 01:00:13 GMT</pubDate>
      <guid>https://rip.trb.org/View/1278688</guid>
    </item>
    <item>
      <title>Evaluation of the Orientation of 90 ° and 180° Reinforcing Bar Hooks in Wide Members</title>
      <link>https://rip.trb.org/View/1253621</link>
      <description><![CDATA[Longitudinal reinforcing steel in concrete flexural elements is often developed at the end of a concrete member by a 90° or 180° standard hook that is usually oriented such that the hook is in the vertical direction. In some instances, such as the case of a shallow member that is heavily-reinforced with reinforcing bars of large diameter, the standard hook height in plus concrete cover above and below the bar may exceed the thickness of the concrete member. To address this issue, sometimes it is suggested that the hook may tilted from vertical to maintain the required clear cover. The limits of this tilt, however, are not defined or known. To address this issue, the overall goal of the proposed project is to study the influence of tilt angle on the development of standard reinforcing bar hooks and determine determine the limits of reinforcing steel hook tilt, if any, so ultimate performance of the member is not compromised. Design recommendations developed as part of this study will provide clarification to engineers and building code officials regarding limits of tilt of hooked reinforcing bars so that the original intent of hooked bar development is met.]]></description>
      <pubDate>Wed, 26 Jun 2013 01:00:08 GMT</pubDate>
      <guid>https://rip.trb.org/View/1253621</guid>
    </item>
    <item>
      <title>Evaluation of the Orientation of 90° and 180° Reinforcing Bar Hooks in Wide Members</title>
      <link>https://rip.trb.org/View/1234470</link>
      <description><![CDATA[Longitudinal reinforcing steel in concrete flexural elements is often developed at the end of a concrete member by a 90° or 180° standard hook that is usually oriented such that the hook is in the vertical direction. In some instances, such as the case of a shallow member that is heavily-reinforced with reinforcing bars of large diameter, the standard hook height in plus concrete cover above and below the bar may exceed the thickness of the concrete member. To address this issue, sometimes it is suggested that the hook may tilted from vertical to maintain the required clear cover. The limits of this tilt, however, are not defined or known. To address this issue, the overall goal of the proposed project is to study the influence of tilt angle on the development of standard reinforcing bar hooks and determine determine the limits of reinforcing steel hook tilt, if any, so ultimate performance of the member is not compromised. Design recommendations developed as part of this study will provide clarification to engineers and building code officials regarding limits of tilt of hooked reinforcing bars so that the original intent of hooked bar development is met.]]></description>
      <pubDate>Thu, 03 Jan 2013 15:12:59 GMT</pubDate>
      <guid>https://rip.trb.org/View/1234470</guid>
    </item>
    <item>
      <title>Construction of Crack-Free Concrete Bridge</title>
      <link>https://rip.trb.org/View/1229936</link>
      <description><![CDATA[Cracks in concrete bridge decks provide easy access for water and deicing chemicals (chlorides) that shorten the life of the deck due to freeze-thaw damage and corrosion of reinforcing steel. Measurements show that high quality concrete can significantly slow the penetration of chlorides to the level of the reinforcing steel. In contrast, measurements taken at cracks show that the chloride content of the concrete can exceed the corrosion threshold at the level of the reinforcing steel by the end of the first winter. An ongoing two-phase Pooled-Fund study at Kansas University (KU), anchored by the Kansas Department of Transportation, is aimed at reducing cracking in concrete bridge decks using better design, construction, and material specifications. The purpose of the study is to work with participating states, Transportation Research Institute (TRI), and industrial partners to use new materials and modified construction techniques to construct crack-free bridge decks.]]></description>
      <pubDate>Thu, 03 Jan 2013 13:51:03 GMT</pubDate>
      <guid>https://rip.trb.org/View/1229936</guid>
    </item>
  </channel>
</rss>