<rss version="2.0" xmlns:atom="https://www.w3.org/2005/Atom">
  <channel>
    <title>Research in Progress (RIP)</title>
    <link>https://rip.trb.org/</link>
    <atom:link href="https://rip.trb.org/common/TRIS Suite/feeds/RSS.aspx?s=PHNlYXJjaD48cGFyYW1zPjxwYXJhbSBuYW1lPSJkYXRlaW4iIHZhbHVlPSJhbGwiIC8%2BPHBhcmFtIG5hbWU9InN1YmplY3Rsb2dpYyIgdmFsdWU9Im9yIiAvPjxwYXJhbSBuYW1lPSJ0ZXJtc2xvZ2ljIiB2YWx1ZT0ib3IiIC8%2BPHBhcmFtIG5hbWU9ImxvY2F0aW9uIiB2YWx1ZT0iMTYiIC8%2BPC9wYXJhbXM%2BPGZpbHRlcnM%2BPGZpbHRlciBmaWVsZD0iaW5kZXh0ZXJtcyIgdmFsdWU9IiZxdW90O0NhYmxlcyZxdW90OyIgb3JpZ2luYWxfdmFsdWU9IiZxdW90O0NhYmxlcyZxdW90OyIgLz48L2ZpbHRlcnM%2BPHJhbmdlcyAvPjxzb3J0cz48c29ydCBmaWVsZD0icHVibGlzaGVkIiBvcmRlcj0iZGVzYyIgLz48L3NvcnRzPjxwZXJzaXN0cz48cGVyc2lzdCBuYW1lPSJyYW5nZXR5cGUiIHZhbHVlPSJwdWJsaXNoZWRkYXRlIiAvPjwvcGVyc2lzdHM%2BPC9zZWFyY2g%2B" rel="self" type="application/rss+xml" />
    <description></description>
    <language>en-us</language>
    <copyright>Copyright © 2026. National Academy of Sciences. All rights reserved.</copyright>
    <docs>http://blogs.law.harvard.edu/tech/rss</docs>
    <managingEditor>tris-trb@nas.edu (Bill McLeod)</managingEditor>
    <webMaster>tris-trb@nas.edu (Bill McLeod)</webMaster>
    <image>
      <title>Research in Progress (RIP)</title>
      <url>https://rip.trb.org/Images/PageHeader-wTitle-RIP.jpg</url>
      <link>https://rip.trb.org/</link>
    </image>
    <item>
      <title>Salem District Distributed Acoustic Sensing Pilot on I-81: Performance Evaluation Research Proposal</title>
      <link>https://rip.trb.org/View/2778217</link>
      <description><![CDATA[Virginia Department of Transportation (VDOT) has an extensive network of fiber optic cables that provide the opportunity for Distributed Acoustic Sensing (DAS) to monitor traffic. DAS operates on existing dark (i.e., unused) fibers, using vibrations to characterize events such as passing cars or incidents like vehicles stopping or crossing over rumble strips. By following traces along a cable, these systems can often identify vehicle trajectories and impute speeds and vehicle class. The accuracy and sensitivity of DAS systems is greatly impacted by fiber installation parameters, including the cable type, installation method, depth, and distance from the roadway. This has the potential to greatly add to VDOT’s sensing space along rural roads without additional capital investment, supplementing existing camera systems. Salem District is piloting a DAS unit at three different sites to determine its effectiveness for TOC alerts of events like disabled vehicles. This project will evaluate the system’s effectiveness for alerts and traffic parameter measurements, enumerate considerations for statewide deployment, and study how VDOT’s fiber installation policies impact DAS sensing capabilities.]]></description>
      <pubDate>Thu, 17 Sep 2026 09:02:23 GMT</pubDate>
      <guid>https://rip.trb.org/View/2778217</guid>
    </item>
    <item>
      <title>Efficacy, Advancement, and Monitoring of Carbon Fiber Composite Cable (CFCC)</title>
      <link>https://rip.trb.org/View/2724770</link>
      <description><![CDATA[Carbon Fiber Composite Cable (CFCC), and the Carbon Fiber Reinforced Polymer (CFRP) materials are being used for prestressing
applications in Michigan bridge rehabilitation and replacement projects with the most recent generation of CFCC is a 0.7-inch strand
configuration. The quantity of stands is similar to conventional strands, and concomitant updated design criteria. Determining the
efficacy of the new 0.7-inch CFCC strand long-term behavior is essential for future design and construction considerations.
Monitoring the CFCC elements in newly constructed bridges (with 0.7-inch strands) and some prior construction (from OR14-039)
will provide an understanding of the long-term behavior and realizations of recommendations on future designs, and continued
considerations of field deployment.]]></description>
      <pubDate>Tue, 07 Jul 2026 10:05:57 GMT</pubDate>
      <guid>https://rip.trb.org/View/2724770</guid>
    </item>
    <item>
      <title>High Tension Cable Median Guardrail Expected Lifespan</title>
      <link>https://rip.trb.org/View/2487331</link>
      <description><![CDATA[The Minnesota Department of Transportation (MnDOT) has been installing High Tension Cable Barrier (HTCB) Systems for approximately 20 years along heavily traveled corridors. The objective of this research is to study the lifecycle of HTCB system and the inspection process for this critical safety equipment.]]></description>
      <pubDate>Wed, 08 Oct 2025 09:59:25 GMT</pubDate>
      <guid>https://rip.trb.org/View/2487331</guid>
    </item>
    <item>
      <title>Investigation and Validation of V-Ditch Traversability Related to Crash Testing Cable Barrier Systems</title>
      <link>https://rip.trb.org/View/2381739</link>
      <description><![CDATA[The 2016 American Association of State Highway and Transportation Officials (AASHTO) Manual for Assessing Safety Hardware (MASH) provides full-scale test matrices for evaluating cable median barriers on level terrain and sloped median ditches. The matrices define the critical placement of cable barriers and test criteria for 4:1 (horizontal to vertical slope) and 6:1 V-ditches to evaluate the safety performance of cable median barriers. Recent full-scale crash testing of cable median barriers under the conditions described in MASH Test No. 3-16 have produced varying results for the stability of small vehicles traversing 4:1 V-ditches.

MASH Test No. 3-16 uses a 46-ft-wide V-ditch as measured from slope break point to slope break point, with the cable barrier test article placed 4 ft from the slope break point on the far side of the V-ditch. However, small vehicles have experienced inconsistent stability while traversing the 4:1 V-ditches during crash testing, and the AASHTO Roadside Design Guide (RDG) notes that 4:1 V-ditches are not a preferred configuration for median V-ditches. This raises concerns that the traversability of the V-ditch configuration used in MASH 2016 may be near the limit of vehicle stability.

Research is needed to investigate the traversability of 4:1 V-ditches to verify if the current configuration specified in MASH Test No. 3-16 produces sufficient vehicle stability for consistent and reliable test article impact conditions.

OBJECTIVE: The objective of this research is to investigate the traversability of 4:1 V-ditches for crash testing of cable median barrier systems.

]]></description>
      <pubDate>Wed, 22 May 2024 11:49:24 GMT</pubDate>
      <guid>https://rip.trb.org/View/2381739</guid>
    </item>
    <item>
      <title>Veterans' Glass City Skyway Bridge Main Cable Evaluation</title>
      <link>https://rip.trb.org/View/2219042</link>
      <description><![CDATA[The main span of the Veterans' Glass City Skyway (VGCS) Bridge over the Maumee River is a cable stayed structure. The bridge has a single row of stay cables comprised of epoxy coated strand that are encased in stainless steel sheathing.  Nondestructive inspection methods of these bridges are limited and can be expensive. This issue is compounded when the cables are encased in stainless steel sheathing like the VGCS. The ability to detect corrosion, pitting or other defects that can impact the cable is essential to ensure the safety of the traveling public and the longevity of the bridge.  Currently, it is unclear if a technology is available that can obtain data to evaluate the condition of cables encased in stainless steel. Ohio Department of Transportation (ODOT) is unaware of any attempts to fully test existing methods to determine the viability and effectiveness of existing procedures. Research is needed to determine if current methods/technologies are capable of evaluating the condition of epoxy coated strands encased in stainless steel.

The goal of this research is to determine a systematic method for monitoring and assessing the condition of the epoxy coated strands in the stay cables. The objective of this research is to identify a practical, nondestructive way to evaluate the condition of the epoxy coated strands in the stay cables using existing and available technologies. This research may provide ODOT with the ability to determine the condition of the stay cables on the VGCS. Answering the question of whether or not strands encased in stainless steel can be assessed or even seen through current methods is an essential first step to ensuring the soundness of these structures.      ]]></description>
      <pubDate>Mon, 24 Jul 2023 16:02:13 GMT</pubDate>
      <guid>https://rip.trb.org/View/2219042</guid>
    </item>
    <item>
      <title>Residual cable strength fatigue testing</title>
      <link>https://rip.trb.org/View/2096580</link>
      <description><![CDATA[This research involves residual cable strength fatigue testing following blast and fire events. There are other potential interested partners since 2015 regarding this activity that was started and this funding will supplement a collaborative effort.]]></description>
      <pubDate>Fri, 13 Jan 2023 14:49:23 GMT</pubDate>
      <guid>https://rip.trb.org/View/2096580</guid>
    </item>
    <item>
      <title>Influence of Revising CFCC Guaranteed Strength on Performance of CFCC Prestressed Highway Bridge Beams Subjected to Various Environmental Conditions</title>
      <link>https://rip.trb.org/View/1994154</link>
      <description><![CDATA[Based on extensive tensile test results, the manufacturer of carbon fiber composite cable (CFCC) strands updated the guaranteed breaking load of different strand diameters to reflect the current material strength with the proper safety margin. The guaranteed breaking load of 0.6-in. CFCC strands increased from 60.7 kip to 66.2 kip. Similarly, the guaranteed breaking load of 0.7-in. CFCC strands increased from 78.7 kip to 86.6 kip. The new guaranteed breaking loads are corresponding to a guaranteed strength of 370 ksi
for both diameters. The increase in the guaranteed strength ensures an efficient and economical use of the material. Nevertheless, implementing the new value in the design and construction of highway bridge beams necessitates the support of comprehensive
experimental and analytical investigations to adequately predict the performance of the constructed beams under different loads and environmental conditions. This will be similar to the extensive experimental and numerical modeling program conducted for the 0.6-in
CFCC strands.]]></description>
      <pubDate>Thu, 14 Jul 2022 12:59:23 GMT</pubDate>
      <guid>https://rip.trb.org/View/1994154</guid>
    </item>
    <item>
      <title>Guidelines for Risk-Based Inspection and Strength Evaluation of Suspension Bridge Main Cable Systems</title>
      <link>https://rip.trb.org/View/1472755</link>
      <description><![CDATA[Since its publication in 2004, NCHRP Report 534: Guidelines for Inspection and Strength Evaluation of Suspension Bridge Parallel Wire Cables, has become a nationally recognized guideline. Because of the complexity of the technical information presented in the NCHRP Report 534 and the unique nature of suspension bridges, the FHWA published a Primer for the Inspection and Strength Evaluation of Suspension Bridge Cables in May 2012 to supplement NCHRP Report 534. The Primer expanded the information in NCHRP Report 534 and offered additional resources for agencies planning and performing inspections, metallurgical testing, and strength evaluations of suspension bridge main cables. Significant progress has been made by researchers and bridge owners over the last decade to advance risk-based inspection methods, nondestructive evaluation (NDE) techniques, structural health monitoring (SHM), and strength evaluation methods. There is an immediate need to incorporate these advances into the current practices for inspection and evaluation of suspension main cable systems.
 
The objectives of this research were to (1) develop guidelines for risk-based inspection and strength evaluation of suspension bridge main cable systems using probabilistic approaches and (2) plan and conduct a workshop for suspension cable bridge owners to demonstrate the use of proposed guidelines. The guidelines are presented in a format suitable for adoption by AASHTO. 
]]></description>
      <pubDate>Tue, 04 Jul 2017 10:32:01 GMT</pubDate>
      <guid>https://rip.trb.org/View/1472755</guid>
    </item>
    <item>
      <title>Integrated Health Monitoring and Reinforcement of
Transportation Structures with Optimized Low-Cost
Multifunctional Braided Cables</title>
      <link>https://rip.trb.org/View/1467520</link>
      <description><![CDATA[Shape memory alloy (SMAs) can produce large recoverable deformations triggered by stress in a response known as superelasticity. This response has been shown to limit the damage sustained by the structure from an adverse event such as earthquakes, and have been considered in a range of civil engineering applications. Through a combined approach of structural optimization and materials design, this research aims at simultaneously achieving advantageous mechanical properties and self-monitoring capabilities in a single material for transportation structures. Therefore, the objective of this collaborative research is to design, fabricate, and characterize multifunctional high strength and self-sensing braided cables structures using novel iron-based SMAs.  The system will exploit unique properties of recently developed low-cost superelastic FeMnAlNi SMAs, which enables excellent superelastic properties, high strength, and self-sensing in structural health monitoring.  At the conclusion of the technical portion of the project, the researchers are expected to demonstrate a braided iron-based SMA cable capable of sustaining higher stress and greater elongation before yielding than conventional high strength steel cables of an identical geometry. For the implementation phase of the project, the authors will show that the strain in the braided Fe-SMA cable directly correlates with changes in its magnetic response, and can be converted into structural deflections using simple instruments.  Additionally, the project will define a viable path for technology transfer by establishing substantive partnerships with commercial alloy manufacturers, and cultivate the awareness and expertise in the technology through workforce development and outreach activities.  
]]></description>
      <pubDate>Sun, 21 May 2017 10:07:06 GMT</pubDate>
      <guid>https://rip.trb.org/View/1467520</guid>
    </item>
    <item>
      <title>Transit Traction Power Cables: Replacement Guidelines</title>
      <link>https://rip.trb.org/View/1442154</link>
      <description><![CDATA[The transit industry uses insulated cable for traction power supply and negative return cables between traction power substations, tie switches, and points of delivery to the vehicles, whether third (contact) rail or overhead contact system (OCS). In addition, third rail systems use jumper cables to provide continuity of power around third rail gaps and expansion joints. The conductor insulation system used for traction power cables as well as for lower voltage power distribution and signal/communication systems typically has a specified life of 30 years. Many of the transit systems in the United States are that age or older with original cables still in service.
 
Many cables within transit tunnels have had failures because of the water penetration through and around the cable insulation, causing damage to the insulation and corrosion of the copper conductor. In some subway tunnels, the conduits themselves have degraded to the point where they cannot be cleaned out and reused for their original purpose. Transit systems have experienced cable fires and system-wide closures due to the degradation of traction power cable insulation. In recent years, major storms affecting the United States have inundated transit tunnels with fresh and contaminated water and exacerbated cable lifecycle concerns.
 
Research is needed to answer key questions and to determine end of life and replacement criteria for transit traction power cables.
 
OBJECTIVE: The objective of this research is to develop guidelines for determining when to replace transit system cables. The research will include a study of current practices for (1) assessing insulation aging and (2) replacement of cables before failure, including (a) approaches used in transit systems for which there are no monitoring programs and/or testing systems, (b) factors affecting life of cable, and (c) effective practices from transit agencies.
 
]]></description>
      <pubDate>Sat, 07 Jan 2017 13:15:12 GMT</pubDate>
      <guid>https://rip.trb.org/View/1442154</guid>
    </item>
    <item>
      <title>Performance Evaluation of Cable Barriers on a 6:1 Sloped Median under MASH TL-3 Conditions</title>
      <link>https://rip.trb.org/View/1423744</link>
      <description><![CDATA[The main objective of the proposed research is to evaluate the performance of the current cable median barrier (CMB) design and two retrofit options under Manual for Assessing Safety Hardware (MASH) testing criteria. Finite element modeling and simulations will be employed as the major tool of the investigation. The evaluation will be based on TL-3 conditions, i.e., under the impact of an 1100C small passenger car and a 2270P pickup truck.  All three CMB designs will be placed on a 6H:1V sloped median and impacted by these two vehicles at 100 km/hour and a 25 degree angle.

The research will provide recommendations to North Carolina Department of Transportation (NCDOT) engineers and officials the better option of the two retrofit CMB designs under MASH safety criteria. The evaluation results of the current CMB design and the other retrofit design will also be provided to NCDOT engineers. The research results will help NCDOT officials in their ability to evaluate and communicate their efforts to enhance highway safety. The results will help further improve the performance of current roadside safety devices through economical retrofit options.
]]></description>
      <pubDate>Mon, 19 Sep 2016 16:14:42 GMT</pubDate>
      <guid>https://rip.trb.org/View/1423744</guid>
    </item>
    <item>
      <title>Statewide Overall CFRP Bridge Monitoring</title>
      <link>https://rip.trb.org/View/1280976</link>
      <description><![CDATA[Over the last two decades, the Michigan Department of Transportation (MDOT) has deployed Carbon Fiber Composite Cable (CFCC) and other Carbon Fiber Reinforced Polymer (CFRP) materials in the construction of four bridges. As part of using this innovative material on projects, MDOT developed Experimental Work Plans as required by the Federal Highway Administration (FHWA). Part of these experimental work plans included long term monitoring for the purposes reporting performance information to FHWA. In addition, there are several bridges currently under construction or under consideration for design and construction using CFRP reinforcement. As CFRP is still considered an innovative material, the long-term performance of CFRP materials remains an outstanding area of investigation. Therefore, all Michigan built CFRP bridges have been instrumented with several sensors to capture responses such as strain, deflection, and internal temperatures caused by moving traffic and environmental changes as well. Continued monitoring of the CFR and CFRP elements in these bridges will provide critical information on the long term behavior of CFRP, which will allow for recommendations to be made for future designs and for the development of design guidelines for the state of Michigan taking into account the behavior of current field deployments. The proposed monitoring investigation will utilize the on-board sensors to create a complete profile for the long-term behavior of CFRP under typical Michigan traffic and environmental conditions. The product of this research will benefit MDOT and other state Departments of Transportation (DOTs) in their deployment of CFRP materials in field projects. This will promote the design and construction of bridges with longer lifespans and minimum maintenance costs.]]></description>
      <pubDate>Fri, 20 Dec 2013 01:00:15 GMT</pubDate>
      <guid>https://rip.trb.org/View/1280976</guid>
    </item>
    <item>
      <title>Short-Term Evaluation of a Bridge Cable Using Acoustic Emission Sensors</title>
      <link>https://rip.trb.org/View/1231814</link>
      <description><![CDATA[The Varina-Enon Bridge carries I-295 across the James River and crosses over the shipping channel that leads to the Richmond (Virginia) Marine Terminal. The bridge is a cable-stayed bridge that was opened to traffic in July 1990. It has 150 ft of vertical navigational clearance and 630 ft of horizontal navigational clearance. The overall bridge length is 4,686 ft. The bridge has six lanes (three each way) with full right and left shoulders. This study used acoustic emission (AE) to assess the condition of strands by examining for active defects (such as corrosion, crack expansion and rubbing, wire breaks, and similar active defects) on a single stay-cable, from anchorage point to anchorage point, of the Varina-Enon Bridge. Testing was performed over short durations of time during periods that included low traffic volumes (acoustically quiet) and high traffic volumes (acoustically noisy). In addition, computer software was used to determine the source and location of the acoustic event. The most significant finding was that AE events were being generated inside the pylon in the saddle region. Further, although AE responses from the stay-cable did not contain any signatures of rubbing from previously broken cable and/or breaking during the testing period, AE signals were detected, possibly because of higher winds or blowing debris striking the cable/anchorage region. The study recommends that the Virginia Department of Transportation's (VDOT) Richmond District Bridge Division 1) measure and map the cracks in the northern and southern stay-cable pylons of the bridge; 2) evaluate the northern pylon saddle regions using AE and determine which areas show the greatest acoustical activity; 3) evaluate the stay-cable anchorage regions more closely using AE; and 4) determine the source of the AE signal that was detected during this study. Finally, the anchorage regions should be evaluated. VDOT should consider using AE periodically to evaluate the health of this structure and determine which regions are exhibiting significant AE activity. Regions with elevated AE activity should take precedence over non-active regions during inspection.]]></description>
      <pubDate>Thu, 03 Jan 2013 14:26:38 GMT</pubDate>
      <guid>https://rip.trb.org/View/1231814</guid>